HNG Series

Produce your nitrogen needs continuously with HERTZ HNG series Nitrogen Generator. Save time, money and space. HNG series are very easy to use with its simple structure, compact design and fully automated operation.

Description

Model Buffer Tank Connections Dimensions (mm) Weight
Air Inlet Nitrogen Outlet Length Width Height Kg
HNG 10 26 L G ½” G ½” 670 500 1130 40
HNG 20 35 L G ½” G ½” 1043 596 1284 67
HNG 35 52 L G ½” G ½” 1082 689 1278 86
HNG 60 70 L G ½” G ½” 1100 890 1433 124
HNG 95 97 L G ½” G ½” 1659 760 1485 184
HNG 120 126 L G ½” G ½” 1634 890 1442 228
HNG 150 151 L G ½” G ½” 1634 890 1639 313
HNG 250 280 L G ¾” G ½” 1760 892 1975 491
HNG 330 408 L G 1″ G ½” 1901 950 2025 692
HNG 450 464 L G 1″ G ½” 2218 1010 2134 677
HNG 510 515 L G 1″ G ¾” 2208 1010 2028 912
HNG 570 573 L G 1″ G ¾” 2208 1010 2226 951
HNG 730 712 L G 1″ G ¾” 2685 1110 2084 1091
HNG 910 1,0 m3 G 1 ½” G 1″ 2727 1220 2485 1395
HNG 1110 1,3 m3 G 1 ½” G 1″ 2896 1322 2521 1704
HNG 1230 1,4 m3 G 2″ G 1″ 2898 1322 2724 2031
HNG 1370 1,5 m3 G 2″ G 1 ¼” 2895 1355 2941 2096
HNG 1820 2,0 m3 G 2″ G 1 ½” 3599 1793 2634 2686
HNG 2050 2,3 m3 DN80 G 1 ½” 3390 1964 3124 3009
HNG 2550 2,3 m3 DN80 G 2″ 3666 2139 3194 3040
HNG 2950 2,3 m3 DN80 G 2″ 4074 2245 2787 3065
HNG 3540 2,3 m3 DN80 G 2″ 4024 2375 3054 3214
HNG 4160 2,3 m3 DN80 G 2″ 4020 2376 3361 3466
HNG 5560 2,3 m3 DN100 G 2 ½” 4125 2425 3890 4144
HNG 9170 2,3 m3 DN150 DN80 4502 2986 4364 5298
HNG 11200 2,3 m3 DN150 DN100 3081 4672 4728 5846

Model and Technical information

Model Buffer Tank Connections Dimensions (mm) Weight
Air Inlet Nitrogen Outlet Length Width Height Kg
HNG 10 26 L G ½” G ½” 670 500 1130 40
HNG 20 35 L G ½” G ½” 1043 596 1284 67
HNG 35 52 L G ½” G ½” 1082 689 1278 86
HNG 60 70 L G ½” G ½” 1100 890 1433 124
HNG 95 97 L G ½” G ½” 1659 760 1485 184
HNG 120 126 L G ½” G ½” 1634 890 1442 228
HNG 150 151 L G ½” G ½” 1634 890 1639 313
HNG 250 280 L G ¾” G ½” 1760 892 1975 491
HNG 330 408 L G 1″ G ½” 1901 950 2025 692
HNG 450 464 L G 1″ G ½” 2218 1010 2134 677
HNG 510 515 L G 1″ G ¾” 2208 1010 2028 912
HNG 570 573 L G 1″ G ¾” 2208 1010 2226 951
HNG 730 712 L G 1″ G ¾” 2685 1110 2084 1091
HNG 910 1,0 m3 G 1 ½” G 1″ 2727 1220 2485 1395
HNG 1110 1,3 m3 G 1 ½” G 1″ 2896 1322 2521 1704
HNG 1230 1,4 m3 G 2″ G 1″ 2898 1322 2724 2031
HNG 1370 1,5 m3 G 2″ G 1 ¼” 2895 1355 2941 2096
HNG 1820 2,0 m3 G 2″ G 1 ½” 3599 1793 2634 2686
HNG 2050 2,3 m3 DN80 G 1 ½” 3390 1964 3124 3009
HNG 2550 2,3 m3 DN80 G 2″ 3666 2139 3194 3040
HNG 2950 2,3 m3 DN80 G 2″ 4074 2245 2787 3065
HNG 3540 2,3 m3 DN80 G 2″ 4024 2375 3054 3214
HNG 4160 2,3 m3 DN80 G 2″ 4020 2376 3361 3466
HNG 5560 2,3 m3 DN100 G 2 ½” 4125 2425 3890 4144
HNG 9170 2,3 m3 DN150 DN80 4502 2986 4364 5298
HNG 11200 2,3 m3 DN150 DN100 3081 4672 4728 5846

General information

HNG Series

HNG 10 / 20 / 35 / 60 / 95 / 120 / 150 / 250 / 330 / 450 / 510 / 570 / 730 / 910 / 1110 / 1230 / 1370 / 1820 / 2050 / 2950 / 3540 / 4160 / 5560 / 9170 / 11200 (Capacity 0,2Nm3/h – 2500Nm3/h; Purity 95 % - 99,999 %)
Pressure Swing Adsorption (PSA) type Nitrogen Generation system is used to separate and enrich Nitrogen from Oxygen employs CMS (Carbon Molecular Sieve) for adsorbent. Carbon Molecular Sieve (CMS) adsorbs Oxygen and Water Vapor molecules under certain pressure - while allowing Nitrogen to pass through. The nitrogen molecules (4.3 Angstrom in size) passes through the column, but the oxygen molecules (3.9 Angstrom in size) are adsorbed on the carbon molecular sieve (4 Angstrom opening). The cycle is composed of following steps PSA Process A. Pressurization Step: Process to increase adsorption pressure in adsorption tower under selected operation condition. B. Adsorption Step: Nitrogen gas is generated under constant pressure. C. Blow Down Step: Restoring in the adsorption tower. D. Purge Step: Stage to restore the adsorption tower completely. E. Pressure Equalization Step: Stage in where loss can be reduced by using a part of energy to be lost.
The Nitrogen Generator consists of two adsorber vessels filled with CMS, a valve assembly, air filters, main pressure regulator, and a product receiver tank. Clean and dry air is directed to one of the adsorber beds where oxygen and water vapor is adsorbed faster than nitrogen in the pore structure of the CMS, thus increasing the nitrogen purity of the product gas stream to the desired level (95 – 99.999 % as required by customer). This product flows out of the top of the adsorber bed, through the valve, and into the product receiver at a pressures lightly below the feed air pressure. Strength to withstand strenuous operating conditions Protection from oil slugs or compressor Air/ Oil separator failure
Metal Industry Annealing of ferrous and non-ferrous metal (Inert circumstance) Metallurgical heat treatment (Carbonizing) Soldering / Brazing Plasma sheet metal cutters Inert gas in welding process Sintering of metal powder Chemical Industry Transportation of raw material in storage tank Container ventilation and prevention of explosion inreaction tank Sealing of nitrogen in storage tank Cleaning tank and container Pressure testing of pipe Production Process And Storage Of Food Storage of low oxygen CA or super low oxygen Charge of nitrogen gas in packing and transportation of coffee, snack or dry nut Purge Diluting or transposing gas or vapor to eliminate dangerous gas and oxidized substance Plastic Ejecting high pressure gas (Sustaining vacuum, shortening cooling time in Ejection) Suppressing gas generation in ejection Charge Nitrogen Gas In Tire Reducing noise reduction, improving fuel efficiency, reducing tire unbalance and improving driving comport
Hertz Provides Necessary Nitrogen Buffer Tank As Standard! Simple structure, compact design, full automated operation 7/24 Nitrogen production in your own place Touch Screen PLC for controlling the complete system PLC Screen for Monitoring and visualization the progress Rapid start-up Safety system Due to well design of silencer, low noise levels during depressurization and purge Durable piston valves for long-life operation On demand production, low cost High performance. Design the purity and capacity of nitrogen gas meeting to customer’s requirements. (Nitrogen Purity 95 %~99.999 % is available) Minimum maintenance cost replace filter element periodically only and get normal service for the compressor
Oxygen Analyzer Flow Meter Dew Point Sensor Nitrogen purity can be seen on screen

Reviews

There are no reviews yet.

Be the first to review “HNG Series”

Your email address will not be published. Required fields are marked *