Hertz Cycling Dryers consume energy dependent on the air flow. The refrigeration system of the dryer cools down the water-glycol mixture up to 1 0C and store that mixture in a stainless steel tank. A small pump circulates the water-glycol mixture to cool down the compressed air. The compressor of the refrigeration system shuts down after the desired mixture temperature is reached which results in significant energy savings.

Description

 

Model Capacity Connection Size Voltage Max. Working Pressure Max. Ambient Temp. Max. Inlet Temp. Refrigerant Gas Included Filter and Type Dimensions (mm) Weight
m3/min cfm bar °C °C Length Width Height Kg
HRC 495 8.25 291 G 2″ 230V/1/50 Hz 16 50 65 R-134a HGKO 851 MX+MY 855 725 1505 178
HRC 623 10.4 366 G 2″ 230V/1/50 Hz 16 50 65 R-134a HGKO 1210 MX+MY 855 725 1505 184
HRC 930 15.5 547 G 2″ 230V/1/50 Hz 16 50 65 R-134a HGKO 1210 MX+MY 830 730 1765 242
HRC 1200 20 706 G 2″ 400V/3/50Hz 16 50 65 R-134a HGKO 1210 MX+MY 830 730 1765 253
HRC 1388 23.1 817 G 3″ 400V/3/50Hz 16 50 65 R-134a HGKO 1820 MX+MY 1150 800 1740 295
HRC 1800 30 1059 G 3″ 400V/3/50Hz 16 50 65 R-134a HGKO 1820 MX+MY 1150 800 1740 310
HRC 2500 41.7 1471 G 3″ 400V/3/50Hz 16 50 65 R-134a HGKO 1820 MX+MY 1315 880 1790 411
HRC 2775 46.3 1633 G 3″ 400V/3/50Hz 16 50 65 R-134a HGKO 2700 MX+MY 1315 880 1790 443
HRC 3330 55.5 1960 DN100 400V/3/50Hz 16 50 65 R-134a HGKO 2700 MX+MY 1400 850 1840 537
HRC 3915 65.3 2304 DN100 400V/3/50Hz 16 50 65 R-134a N/A 1400 850 1840 557
HRC 5085 84.8 2993 DN100 400V/3/50Hz 16 50 65 R-134a N/A 1620 1080 1995 737
HRC 5850 97.5 3443 DN100 400V/3/50Hz 16 50 65 R-134a N/A 1620 1080 1995 760
HRC 6975 116.3 4105 DN150 400V/3/50Hz 16 50 65 R-134a N/A 2190 1065 2025 941
HRC 7875 131.3 4634 DN150 400V/3/50Hz 16 50 65 R-134a N/A 2190 1065 2025 963
HRC 9000 150 5297 DN150 400V/3/50Hz 16 50 65 R-134a N/A 2900 1200 2120 1025
HRC 10500 175 6179 DN200 400V/3/50Hz 16 50 65 R-134a N/A 2900 1200 2120 1162
HRC 12500 208.3 7356 DN200 400V/3/50Hz 16 50 65 R-134a N/A 2550 1550 2170 1480

Full product specifications

pdf ikona

Models and Technical Information

Model Capacity Connection Size Voltage Max. Working Pressure Max. Ambient Temp. Max. Inlet Temp. Refrigerant Gas Included Filter and Type Dimensions (mm) Weight
m3/min cfm bar °C °C Length Width Height Kg
HRC 495 8.25 291 G 2″ 230V/1/50 Hz 16 50 65 R-134a HGKO 851 MX+MY 855 725 1505 178
HRC 623 10.4 366 G 2″ 230V/1/50 Hz 16 50 65 R-134a HGKO 1210 MX+MY 855 725 1505 184
HRC 930 15.5 547 G 2″ 230V/1/50 Hz 16 50 65 R-134a HGKO 1210 MX+MY 830 730 1765 242
HRC 1200 20 706 G 2″ 400V/3/50Hz 16 50 65 R-134a HGKO 1210 MX+MY 830 730 1765 253
HRC 1388 23.1 817 G 3″ 400V/3/50Hz 16 50 65 R-134a HGKO 1820 MX+MY 1150 800 1740 295
HRC 1800 30 1059 G 3″ 400V/3/50Hz 16 50 65 R-134a HGKO 1820 MX+MY 1150 800 1740 310
HRC 2500 41.7 1471 G 3″ 400V/3/50Hz 16 50 65 R-134a HGKO 1820 MX+MY 1315 880 1790 411
HRC 2775 46.3 1633 G 3″ 400V/3/50Hz 16 50 65 R-134a HGKO 2700 MX+MY 1315 880 1790 443
HRC 3330 55.5 1960 DN100 400V/3/50Hz 16 50 65 R-134a HGKO 2700 MX+MY 1400 850 1840 537
HRC 3915 65.3 2304 DN100 400V/3/50Hz 16 50 65 R-134a N/A 1400 850 1840 557
HRC 5085 84.8 2993 DN100 400V/3/50Hz 16 50 65 R-134a N/A 1620 1080 1995 737
HRC 5850 97.5 3443 DN100 400V/3/50Hz 16 50 65 R-134a N/A 1620 1080 1995 760
HRC 6975 116.3 4105 DN150 400V/3/50Hz 16 50 65 R-134a N/A 2190 1065 2025 941
HRC 7875 131.3 4634 DN150 400V/3/50Hz 16 50 65 R-134a N/A 2190 1065 2025 963
HRC 9000 150 5297 DN150 400V/3/50Hz 16 50 65 R-134a N/A 2900 1200 2120 1025
HRC 10500 175 6179 DN200 400V/3/50Hz 16 50 65 R-134a N/A 2900 1200 2120 1162
HRC 12500 208.3 7356 DN200 400V/3/50Hz 16 50 65 R-134a N/A 2550 1550 2170 1480

Reviews

There are no reviews yet.

Be the first to review “HRC Series”